 Model NO. 10066566 (VisiWater DO P Arc 150 FC10)
 DO ÃøÁ¤ ¹üÀ§ 4 ppb ~ 40 ppm
 ÃøÁ¤ ¿ø¸® LuminescenceÀÇ ±¤ÇÐ ÃøÁ¤¹æ½Ä/¿Âµµº¸»ó
 Á¤È®µµ (25¡ÆC) 0.4 ppm ¡¾5% / 8 ppm ¡¾1% / 20 ppm ¡¾5%
 ¿Âµµ ¹üÀ§ NTC 22k¥Ø 0 ~ 60 ¡É
 ¾Ð·Â ¹üÀ§ -1 ~ 12 bar
 Ãâ·Â ¾Æ³¯·Î±× Ãâ·Â DC 4-20mA (ÇÁ·Î±×·¥ °¡´É)
 µðÁöÅÐ Ãâ·Â RS485 Modbus
 4-20mA current ¹üÀ§ 3.5 ~ 22 mA
 ÀÛµ¿ Àü¾Ð 7 ~ 30 VDC ÃÖ´ë 1W
 ÇÊ¿ä À¯¼Ó ¾øÀ½
 ÀçÁú Shaft : PVC-U  /  Cap : PPA
 ¼¾¼­ Å©±â ⌀ 20 x 150 mm
 ÄÉÀ̺í 10m fix cable
 Æ¯Â¡ ¹× ÀÀ¿ë -¸¶ÀÌÅ©·Î Æ®·»½º¹ÌÅÍ ³»ÀåÇü ¼¾¼­ (º°µµ ±â±â ÇÊ¿ä¾øÀ½)
¡¡ -±¤ÇÐ ¹æ½ÄÀ¸·Î À¯Áöº¸¼ö°¡ ÇÊ¿ä ¾øÀ½
¡¡ -ÀüÇØÁú¿ë¾× ÇÊ¿ä ¾øÀ½
¡¡ -À¯¼Ó¿¡ »ó°ü¾øÀÌ ÃøÁ¤
¡¡ -°ß°íÇÑ PVC ÀçÁú·Î ºÎ½Ä¿¡ °­ÇÔ
¡¡ -ªÀº ºÐ±Ø ½Ã°£°ú ÀÀ´ä¼Óµµ
¡¡ -°íÁ¤Çü 10m cable·Î ¹°¿¡ ³Ö¾î ÃøÁ¤ °¡´É
¡¡ -ArcAir ¼ÒÇÁÆ®¿þ¾î·Î µ¥ÀÌÅÍ È®ÀÎ/º¸Á¤/»óÅÂÁ¤º¸ °¡´É
¡¡ -USB-RS485 Modbus ÄÁ¹öÅÍ(¿É¼Ç)·Î PC¿¡ ½±°Ô ¿¬°á °¡´É
¡¡ -ÀϹݹ° / Æó¼ö / ¾ç¾îÀå »ç¿ë

 

OpticalDO ARC #10066566 (VisiWater DO P Arc 150 FC10)
 

DO ARC sensor

Model NO.

243 100 (OXYFERM FDA ARC)

Range

10 ppb ~ 40 ppm

Accuracy

¡¾ 2 % at 25 ¡ÆC

Required flow

¡Ã 0.03 m/s

Max. CO2 partial pressure

0.01 bar

Process pressure range

0 to 4 bar

Electrode system

Silver platinum combination

Electrolyte

OXYLYTE, alkaline

Membrane

OPTIFLOW FDA

Temperature Range

- Analog interface: 0 to 100 ¡ÆC

- Digital interface: 0 to 130 ¡ÆC

Certificate

CE conformity

Wetted materials

Stainless steel 1.4435, EPDM and silicone with FDA approval

ÀÀ¿ë

- ¹ÙÀÌ¿À, Á¦¾à, Food & À½·á, È­ÇÐ

Operating voltage

7~ 30 VDC max. 150 mW

Åë½Å

- Analog 1 : 420 mA for conductivity, programmable

Analog 2 : 420 mA for temperature, programmable

-Digital RS485 Interface : Modbus RTU protocol

DO ARC sensor #243 100 (OXYFERM FDA ARC)
 

DO ARC sensor

Model NO.

243 163 (VISIFERM DO ARC)

Measuring Method

Optical DO(±¤ÇÐ ¹æ½Ä)

Range

4 ppb / 0.05 ~ 500 %

Accuracy

¡¾ 0.05 %-vol / 21 ¡¾ 0.2 %-vol / 50 ¡¾ 0.5 %-vol

Required flow

None

Oxygen consumption

None

Membrane

None

Polarization Voltage &time

None

Process pressure range

-1 to 12 bar

Temperature Range

-10 to 130 ¡ÆC

Certificate

CE conformity

Wetted materials

Stainless steel 1.4435, EPDM and silicone with FDA approval

Ư¡

- ¸âºê·¹ÀÎ ±³Ã¼ ¹× ±³Á¤ ¾øÀÌ °£´ÜÇÑ ¼¾¼­ ĸ ±³Ã¼

- CO2, SO2 ¿µÇâ ¾øÀ½

- ÀúÇ×·Â Yes : ¿¡Åº¿Ã, ¸Þź¿Ã, H2O2, ethylene oxide, beta-gamma irradiation

- ÀúÇ×·Â NO : ¿°¼Ò°¡½º, À¯±â¿ë¸Å(Ŭ·Î·ÎÆ÷¸§, Åç·ç¿£, ¾Æ¼¼Åæ, Çí»ê)

ÀÀ¿ë

- ¹ÙÀÌ¿À, Á¦¾à, Food & À½·á, ¼öó¸®Àå

Operating voltage

7~ 30 VDC max. 150 mW

Åë½Å

- Analog 1 : 420 mA for conductivity, programmable

Analog 2 : 420 mA for temperature, programmable

-Digital RS485 Interface : Modbus RTU protocol

DO ARC sensor #243 163 (VISIFERM DO ARC)
 

DO ARC sensor

Model NO.

243 110 (OXYGOLD G ARC)

Range

1 ppb ~ 40 ppm

Accuracy

¡¾ 2 % at 25 ¡ÆC

Required flow

¡Ã 0.1 m/s

Max. CO2 partial pressure

0.01 bar

Process pressure range

0 to 12 bar

Electrode system

Silver platinum combination

Electrolyte

OXYLYTE G, alkaline

Membrane

OPTIFLOW

Temperature Range

- Analog interface: 0 to 100 ¡ÆC

- Digital interface: 0 to 130 ¡ÆC

Certificate

CE conformity

ÀÀ¿ë

- º¸ÀÏ·¯¼ö, ¹ßÀü¼Ò, È­ÇÐ, Á¦¾à, ¹ÝµµÃ¼

Operating voltage

7~ 30 VDC max. 150 mW

Åë½Å

- Analog 1 : 420 mA for conductivity, programmable

Analog 2 : 420 mA for temperature, programmable

-Digital RS485 Interface : Modbus RTU protocol

DO ARC sensor #243 110 (OXYGOLD G ARC)
 

DO ARC sensor

Model NO.

243 115 (OXYGOLD B ARC)

Range

8 ppb ~ 40 ppm

Accuracy

¡¾ 2 % at 25 ¡ÆC

Required flow

¡Ã 0.1 m/s

Max. CO2 partial pressure

12 bar

Process pressure range

0 to 12 bar

Electrode system

Silver platinum combination

Electrolyte

OXYLYTE B, acidic

Temperature Range

- Analog interface: 0 to 100 ¡ÆC

- Digital interface: 0 to 130 ¡ÆC

Certificate

CE conformity

Ư¡

- ³ôÀº CO2 ³óµµ¿¡¼­ ÃøÁ¤

- Steam sterilizable

- Autoclavable

- CIP

ÀÀ¿ë

- À½¿ë¼ö, È­ÇÐ, ¸ÆÁÖ

Process connection

PG 13.5

Operating voltage

7~ 30 VDC max. 150 mW

Åë½Å

- Analog 1 : 420 mA for conductivity, programmable

Analog 2 : 420 mA for temperature, programmable

-Digital RS485 Interface : Modbus RTU protocol

DO ARC sensor #243 115 (OXYGOLD B ARC)
 