ȸ»ç¼Ò°³ Á¦Ç°¼Ò°³ °í°´Áö¿ø Á¤º¸¸¶´ç ±â¼úÀÚ·á½Ç
 
ÈÞ´ë¿ë/½ÇÇè½Ç¿ë ÃøÁ¤±â
pH/ISE Meter
DO Meter
Conductivity Meter
Multi Meter
MLSS/Źµµ/ÀÜ·ù¿°¼Ò ÃøÁ¤
¼öÁú´ÙÇ׸ñÃøÁ¤±â
ÁöÇϼö ÀÚµ¿°üÃø¸Á ÃøÁ¤±â
BOD ÈÞ´ë¿ë
COD ÃøÁ¤±â
¼öÁú TMS
ÇöÀ弳ġ¿ë ÄÁÆ®·Ñ·¯
pH/ORP
DO
EC (Àüµµµµ/¿°µµ/ÀúÇ×)
Ion (ISE)
Źµµ / SS / MLSS
ÀÜ·ù¿°¼Ò / ¿ÀÁ¸
Ŭ·Î·ÎÇÊ / ³²Á¶·ù
¸ÖƼ
¾Ç¼¼»ç¸®
Àü±Ø & ¾Ç¼¼»ç¸®
Electrode
Accessories
ISE Electrode
¾Ï¸ð´Ï¾Æ¼ºÁú¼Ò ÀÌ¿Â Kit
Áú»ê¼ºÁú¼Ò ÀÌ¿Â Kit
Çì¹ÐÅÏ
Hamilton »ê¾÷¿ë ¼¾¼­
Hamilton Sensor
ARC µðÁöÅÐ ¼¾¼­
>> Á¦Ç°¼Ò°³ >>
 
pH ARC sensor  (4)   ORP ARC sensor  (0)   DO ARC sensor  (5)  
Conductivity ARC sensor  (2)      
 

pH ARC sensor

Model NO.

243 154 (pHeasy ARC)

Range

0 ~ 14 pH

Zero-Point

0 ¡¾ 20 mV

Accuracy

¡¾ 0.02 pH at 25 ¡ÆC

Sample min conductivity

50 ¥ìS/cm

Temperature Range

- Analog interface : 0 to 110 ¡ÆC

- Digital interface : 0 to 130 ¡ÆC

Process pressure range

0 to 6 bar

Electrolyte

POLISOLVE

Reference System

HAMILTON EVEREF-L

Membrane glass

PHI glass

Diaphragm

2 SINGLE PORE

Certificate

CE conformity

Ư¡

- Steam sterilizable

- Autoclavable

- CIP

- º¸Á¤ ¾øÀÌ ¿¬¼Ó »ç¿ë °¡´É

- °Å²Ù·Î ¼³Ä¡ °¡´É

ÀÀ¿ë

- ¹ÙÀÌ¿À, Á¦¾à, Food & À½¿ë¼ö

Operating voltage

7~ 30 VDC max. 150 mW

Åë½Å

- Analog 1 : 420 mA for conductivity, programmable

Analog 2 : 420 mA for temperature, programmable

-Digital RS485 Interface : Modbus RTU protocol

#242 154 (pHeasy ARC)
 

pH ARC sensor

Model NO.

242 111 (POLILYTE Plus ARC)

Range

0 ~ 14 pH

Zero-Point

0 ¡¾ 20 mV

Accuracy

¡¾ 0.02 pH at 25 ¡ÆC

Sample min conductivity

2 ¥ìS/cm

Temperature Range

- Analog interface : 0 to 110 ¡ÆC

- Digital interface : 0 to 130 ¡ÆC

Process pressure range

0 to 6 bar

Electrolyte

POLISOLVE Plus

Reference System

HAMILTON EVEREF-L

Membrane glass

H glass

Diaphragm

2 SINGLE PORE

Certificate

CE conformity

Ư¡

- Steam sterilizable

- Autoclavable

- Àå½Ã°£ ¾ÈÁ¤ °¡´ÉÇÑ H glass

- °Å²Ù·Î ¼³Ä¡ °¡´É

ÀÀ¿ë

- È­ÇÐ, ¹°

Operating voltage

7~ 30 VDC max. 150 mW

Åë½Å

- Analog 1 : 420 mA for conductivity, programmable

Analog 2 : 420 mA for temperature, programmable

-Digital RS485 Interface : Modbus RTU protocol

#242 111 (POLILYTE Plus ARC)
 

pH ARC sensor

Model NO.

242 120 (EASYFERM Food ARC)

Range

0 ~ 14 pH

Zero-Point

0 ¡¾ 20 mV

Accuracy

¡¾ 0.02 pH at 25 ¡ÆC

Sample min conductivity

100 ¥ìS/cm

Temperature Range

- Analog interface : 0 to 110 ¡ÆC

- Digital interface : 0 to 130 ¡ÆC

Process pressure range

0 to 6 bar

Electrolyte

°¡¾ÐµÈ FOODLYTE

Reference System

HAMILTON EVEREF-F

Membrane glass

HB glass

Diaphragm

HP-COATRAMIC

Certificate

EHEDG*, Biocompatibility Test, CE conformity

Ư¡

- Steam sterilizable

- Autoclavable

- CIP

- ¼¼Á¤°ËÁõ EHEDG ¹× MDT »ýüÀûÇÕ Å×½ºÆ® ¿Ï·á

ÀÀ¿ë

- ¹ÙÀÌ¿À, Food & À½¿ë¼ö, Á¦¾à

Operating voltage

7~ 30 VDC max. 150 mW

Åë½Å

- Analog 1 : 420 mA for conductivity, programmable

Analog 2 : 420 mA for temperature, programmable

-Digital RS485 Interface : Modbus RTU protocol

pH ARC sensor #242 120 (EASYFERM Food ARC)
 

pH ARC sensor

Model NO.

242 091 (EASYFERM Plus ARC)

Range

0 ~ 14 pH

Zero-Point

0 ¡¾ 20 mV

Accuracy

¡¾ 0.02 pH at 25 ¡ÆC

Sample min conductivity

100 ¥ìS/cm

Temperature Range

- Analog interface : 0 to 110 ¡ÆC

- Digital interface : 0 to 130 ¡ÆC

Process pressure range

0 to 6 bar

Electrolyte

°¡¾ÐµÈ PHERMLYTE

Reference System

HAMILTON EVEREF-F

Membrane glass

PHI glass

Diaphragm

HP-COATRAMIC

Certificate

CE conformity

Ư¡

- Steam sterilizable

- Autoclavable

- CIP

- ¹«Àº(silver-free) ÀüÇؾ×

- µ¶¼º¿¡ °­ÇÑ ¡°PHI" pH glass

ÀÀ¿ë

- ¹ÙÀÌ¿À, Food & À½¿ë¼ö, Á¦¾à

Operating voltage

7~ 30 VDC max. 150 mW

Åë½Å

- Analog 1 : 420 mA for conductivity, programmable

Analog 2 : 420 mA for temperature, programmable

-Digital RS485 Interface : Modbus RTU protocol

pH ARC sensor #242 091 (EASYFERM Plus ARC)
 
1